- Report on JINST 014P 0220 Date: April 17, 2020 Author(s): IceCube Collaboration Title: In-situ calibration of the single-photoelectron charge response of the IceCube Received: 2020-02-03 18:24:40.0 Report of referee 1 The authors have responded to all questions/comments raised in our previous report. - Page 17, paragraph \dim source measurement". - Please change the subscript 0.25 to 0.23 Page 18, Section 4.3.1 and Table 2. - No all di?erences are in \sub-percent" level. - HQE red (in the text) is it with the Old Toroid (in the legend)? Also, Standard QE is blue (in the text) w/ New Toroid (in the legend). - Please verify. >Is there a seasonal e?ect, ie. - Fig.11, legend: ... | |