DocuShare is now read-only. Use Google Drive.
The server is currently operating in read-only mode to allow routine maintenance operations to be performed.
Properties cannot be edited at this time.
Surface Cable Assembly (SCA).pptx | |
Handle: | Version-105321 |
Owner: | Feyzi, Farshid (User-1923, ffeyzi:LDAP)DS |
Friday, October 15, 2021 03:27:30 PM CDT | |
Saturday, January 15, 2022 01:26:37 AM CST | |
Modified By: | |
- Surface Cable Assembly (SCA) 1 Purpose 2 (photo of west tower) Pass electrical signals from the down hole main cable to the IceCube Lab Runs from ICL to Surface Junction Box One cable for each Upgrade String (7) Cable Entry 3 surface cables x7 culvert removable panel (photo of west tower) Length Planning: Trench Routes 4 Length Planning: Tower & Bridge Run 5 4.6 9.0 0.9 8.4 [m] slack loop = 2*4.6m tower elevation and bridge = 9 + 0.9 + 8.4m xy routing: 2.5m 2.5 Length Planning: Server Room Routing 6 Distance to patch panel [m] x ≤ 7.7 y ≤ 1.1 z ≤ 2.5 7.7 1.1 2.5 Cable shield connection at ICL server room entry (mid-span strip when installed) 4.3 3.4 Contingency: Trench Re... | |
1 | |
Appears In: | Surface Cable Assembly (SCA).pptx |
DocuShare is now read-only. Use Google Drive.