Main Cable Assembly (MCA).pptx | |
Handle: | Version-105244 |
Owner: | Feyzi, Farshid (User-1923, ffeyzi:LDAP)DS |
Friday, October 15, 2021 03:27:21 PM CDT | |
Saturday, October 23, 2021 12:17:16 PM CDT | |
Modified By: | |
- IceCube Upgrade Main Cable Assembly (MCA) 10/15/2021 MCA 1 Brings electrical signals from the sensors to the surface junction box Similar concept to IceCube’s main cable assembly but different build due to market change Each cable serves one string 3x 7 quad cables + 3 single quads Each pair serves up to 4 DOOMs Strength members to support string weight MCA Diagram Design, Status, Notes (DSN) Controlled Document 2 General Cable Requirements Design, Status, Notes (DSN) Controlled Document 3 Description Requirement Lifetime 30 years or more Cable shield thickness 0.10 mm minimum Copper foil, 100% coverage Cable shield drain wires Minimum of two 0.8mm or larger copper stranded d... | |