Skip to Contents

The server is currently operating in read-only mode to allow routine maintenance operations to be performed.

Properties cannot be edited at this time.

View Properties

Main Cable Assembly (MCA).pptx
Handle: Version-105244
Owner: Feyzi, Farshid (User-1923, ffeyzi:LDAP)DS
Friday, October 15, 2021 03:27:21 PM CDT
Saturday, October 23, 2021 12:17:16 PM CDT
Modified By:
- IceCube Upgrade Main Cable Assembly (MCA) 10/15/2021 MCA 1 Brings electrical signals from the sensors to the surface junction box Similar concept to IceCube’s main cable assembly but different build due to market change Each cable serves one string 3x 7 quad cables + 3 single quads Each pair serves up to 4 DOOMs Strength members to support string weight MCA Diagram Design, Status, Notes (DSN) Controlled Document 2 General Cable Requirements Design, Status, Notes (DSN) Controlled Document 3 Description​ Requirement​ Lifetime​ 30 years or more​ Cable shield thickness 0.10 mm minimum Copper foil, 100% coverage Cable shield drain wires Minimum of two 0.8mm or larger copper stranded d...
1
Appears In: Main Cable Assembly (MCA).pptx